Sample File	C:\Users\Jake\Desktop\AIM Raw\14-8-12 Test Data.S80
Classifier Model	3080
DMA Model	3081
DMA Inner Radius(cm)	0.00937
DMA Outer Radius(cm)	0.01961
DMA Characteristic Length(cm)	0.44369
CPC Model	3775 High Flow
Reference Gas Viscosity (Pa*s)	1.83245e-005
Reference Mean Free Path (m)	6.73e-008
Reference Gas Temperature (K)	296.15
Reference Gas Pressure (kPa)	101.3
Channels/Decade	64
Multiple Charge Correction	TRUE
Nanoparticle Aggregate Mobility Analysis	FALSE
Diffusion Correction	TRUE
Gas Density	0.0012
Units	Concentration (DW)
Weight	Number
Sample #	39
Date	08/12/14
Start Time	10:38:24
Diameter Midpoint
 10.9	424.692
 11.3	9816.01
 11.8	74990.1
 12.2	100079
 12.6	120894
 13.1	141037
 13.6	162613
 14.1	195783
 14.6	225778
 15.1	258921
 15.7	297445
 16.3	338544
 16.8	381943
 17.5	425040
 18.1	476972
 18.8	532216
 19.5	576043
 20.2	630448
 20.9	672684
 21.7	721972
 22.5	775584
 23.3	821933
 24.1	857497
 25.0	894078
 25.9	930452
 26.9	960234
 27.9	974775
 28.9	985349
 30.0	973303
 31.1	954018
 32.2	926913
 33.4	867635
 34.6	812211
 35.9	739681
 37.2	670584
 38.5	591940
 40.0	519851
 41.4	440151
 42.9	368797
 44.5	297709
 46.1	238107
 47.8	185091
 49.6	141295
 51.4	105476
 53.3	78290.7
 55.2	55726
 57.3	39216.2
 59.4	26950
 61.5	18086.3
 63.8	12176.6
 66.1	8429.06
 68.5	5959.76
 71.0	4442.82
 73.7	3583.13
 76.4	2969.96
 79.1	2883.99
 82.0	2734.4
 85.1	2278.93
 88.2	1854.12
 91.4	1670.82
 94.7	1407.94
 98.2	1109.07
101.8	973.848
105.5	763.715
109.4	666.577
113.4	550.383
117.6	439.896
121.9	383.534
126.3	336.24
131.0	309.97
135.8	296.484
140.7	199.008
145.9	190.965
151.2	184.679
156.8	125.814
162.5	136.529
168.5	134.29
174.7	117.734
181.1	98.8847
187.7	65.6096
194.6	51.079
201.7	99.1981
209.1	59.0718
216.7	66.9372
224.7	59.8621
232.9	37.8398
241.4	30.9941
250.3	38.5749
259.5	28.3719
269.0	45.3484
278.8	31.074
289.0	18.0284
299.6	29.6727
310.6	22.4593
322.0	18.1042
333.8	18.728
346.0	15.3807
358.7	17.7825
371.8	15.4639
385.4	19.8441
399.5	32.2694
414.2	4.63784
429.4	18.9074
445.1	10.9954
461.4	17.1383
478.3	10.926
Scan Up Time(s)	120
Retrace Time(s)	15
Down Scan First	FALSE
Scans Per Sample	1
Impactor Type(cm)	0.071
Sheath Flow(lpm)	5
Aerosol Flow(lpm)	0.5
CPC Inlet Flow(lpm)	1.5
CPC Sample Flow(lpm)	0.3
Low Voltage	10.1707
High Voltage	9859.19
Lower Size(nm)	10.7461
Upper Size(nm)	486.968
Density(g/cc)	1
Title	
Status Flag	Normal Scan
td(s)	2.258
tf(s)	4.51249
D50(nm)	1076.23
Median(nm)	27.1296
Mean(nm)	28.1011
Geo. Mean(nm)	26.6553
Mode(nm)	28.9026
Geo. Std. Dev.	1.38635
Total Concentration(#/cm)	2.26529e+007
Comment	